SC error code 6, GLE error code 53 Could not
set up IPC connection to target computer
To set up an IPC connection, these requirements should be met:
1.
|
TCP/IP stack installed on the computer where ERAS is installed,
as well as on the target computer. |
2.
|
File and Printer Sharing for Microsoft Network must be
installed. |
3.
|
File sharing ports must be open (135-139, 445). |
4.
|
The target computer must answer ping requests. |
SC error code 6, GLE error code 67 Could not
install ESET installer on target computer
The administrative share ADMIN$ must be
accessible on the clients system drive.
SC error code 6, GLE error code 1326 Could
not set up IPC connection to target computer, probably due to
a wrong username or password
Administrators username and password have not been typed
incorrectly or have not been entered at all.
SC error code 6, GLE error code 1327 Could
not set up IPC connection to target computer
Administrators password field is blank. A remote push
installation cannot work with a blank password field.
SC error code 11, GLE error code 5 Could not
install ESET installer on target computer
The installer cannot access the client computer due to insufficient
access rights (Access Denied).
SC error code 11, GLE error code 1726 Could
not install NOD32 Installer onto target computer
This error code displays after repeated attempts to install if the
Push Installation window was not closed after the first
attempt.
|