The PrimaryStabilizationDelay property gets or sets the time (in minutes) during which the primary Configuration Storage server must be continuously available before an array member will reconnect to it.
HRESULT put_PrimaryStabilizationDelay( long lPrimaryStabilizationDelay ); HRESULT get_PrimaryStabilizationDelay( long* plPrimaryStabilizationDelay );
Pointer to a variable that is set on return to a 32-bit integer specifying the time (in minutes) during which the primary Configuration Storage server must be continuously available before an array member will reconnect to it.
A 32-bit integer that specifies the time (in minutes) during which the primary Configuration Storage server must be continuously available before an array member will reconnect to it.
These property methods return S_OK if the call is successful; otherwise, they return an error code.
Property PrimaryStabilizationDelay As Long
A 32-bit integer that specifies the time (in minutes) during which the primary Configuration Storage server must be continuously available before an array member will reconnect to it.
Sub SetPrimaryStabilizationDelay(css, userName, domain, password, newValue)
' Declare the objects needed.
Dim root ' The FPCLib.FPC root object
Dim isaArray ' An FPCArray object
Dim cssCn ' An FPCConfigurationStorageServerConnection object
Dim currentValue ' An Integer
' Create the root object.
Set root = CreateObject("FPC.Root")
' Connect to the Configuration Storage server.
root.ConnectToConfigurationStorageServer css, userName, domain, password
' Get references to the array object
' and the connection object.
Set isaArray = root.GetContainingArray()
Set cssCn = isaArray.ConfigurationStorageServerConnection
' Change the value of the property if necessary.
currentValue = cssCn.PrimaryStabilizationDelay
WScript.Echo "Current primary stabilization delay: " & currentValue
If newValue <> currentValue Then
cssCn.PrimaryStabilizationDelay = newValue
WScript.Echo "Saving the new value " & newValue & " ..."
isaArray.Save
WScript.Echo "Done!"
End If
End Sub
This property is read/write. Its default value is 10 minutes, and its range of permissible values is from 1 through 99,999.
| Client | Requires Windows Vista or Windows XP. |
|---|---|
| Server | Requires Windows Server 2008. |
| Version | Requires Forefront Threat Management Gateway (TMG). |
| IDL |
Declared in Msfpccom.idl. |
| DLL |
Requires Msfpccom.dll. |
FPCConfigurationStorageServerConnection
Send comments about this topic to Microsoft
Build date: 11/30/2009
© 2008 Microsoft Corporation. All rights reserved.