The PrimaryTestingDelay property gets or sets the time (in minutes) after which an array member will start testing for connectivity with the primary Configuration Storage server when using the alternate Configuration Storage server.
HRESULT put_PrimaryTestingDelay( long lPrimaryTestingDelay ); HRESULT get_PrimaryTestingDelay( long* plPrimaryTestingDelay );
Pointer to a variable that is set on return to a 32-bit integer specifying the time (in minutes) after which an array member will start testing for connectivity with the primary Configuration Storage server when using the alternate Configuration Storage server.
A 32-bit integer that specifies the time (in minutes) after which an array member will start testing for connectivity with the primary Configuration Storage server when using the alternate Configuration Storage server.
These property methods return S_OK if the call is successful; otherwise, they return an error code.
Property PrimaryTestingDelay As Long
A 32-bit integer that specifies the time (in minutes) after which an array member will start testing for connectivity with the primary Configuration Storage server when using the alternate Configuration Storage server.
Sub SetPrimaryTestingDelay(css, userName, domain, password, newValue) ' Declare the objects needed. Dim root ' The FPCLib.FPC root object Dim isaArray ' An FPCArray object Dim cssCn ' An FPCConfigurationStorageServerConnection object Dim currentValue ' An Integer ' Create the root object. Set root = CreateObject("FPC.Root") ' Connect to the Configuration Storage server. root.ConnectToConfigurationStorageServer css, userName, domain, password ' Get references to the array object ' and the connection object. Set isaArray = root.GetContainingArray() Set cssCn = isaArray.ConfigurationStorageServerConnection ' Change the value of the property if necessary. currentValue = cssCn.PrimaryTestingDelay WScript.Echo "Current primary testing delay: " & currentValue If newValue <> currentValue Then cssCn.PrimaryTestingDelay = newValue WScript.Echo "Saving the new value " & newValue & " ..." isaArray.Save WScript.Echo "Done!" End If End Sub
This property is read/write. Its default value is 360 minutes (6 hours), and its range of permissible values is from 1 through 99,999.
Client | Requires Windows Vista or Windows XP. |
---|---|
Server | Requires Windows Server 2008. |
Version | Requires Forefront Threat Management Gateway (TMG). |
IDL |
Declared in Msfpccom.idl. |
DLL |
Requires Msfpccom.dll. |